Yamaha vezérlők által támogatott fieldbus rendszerek
LCC140 (vezérlő LCM100-hoz)
Basic specifications for network modules
Item | Network modules CC-Link |
---|---|
Applicable controllers | LCC140 |
CC-Link compatible version | Ver. 1.10 |
Remote station type | Remove device station |
Number of occupied stations | Fixed to 2 stations |
Station number | 1 to 63 (Set from HPB) |
Communication speed | 10M/5M/2.5M/625K/156Kbps (Set using HPB or POPCOM+.) |
Shortest length between stations | 0.2 m or more |
Total length | 100m/10Mbps, 160m/5Mbps, 4000m/2.5Mbps, 900m/625Kbps, 1200m/156Kbps |
Monitor LED | None |
CC-Link I/O points | General-purpose input 32 points, General-purpose output 32 points Dedicated input 16 points, Dedicated output 16 points Input register 8 words Output register 8 words |
Basic specifications for network modules
Item | Network modules DeviceNet™ | |
---|---|---|
Applicable controllers | LCC140 | |
Applicable DeviceNet™ specifications | Volume 1 Release2.0 Volume 2 Release2.0 |
|
DeviceNet™ Conformance test | Compliant with CT24 | |
Device profile/Device type number | Generic Device(keyable) / 2B Hex | |
Vendor name/Vendor ID | YAMAHA MOTOR CO.,LTD. / 636 | |
Product code | 21 | |
Product revision | 1.0 | |
EDS file name | Yamaha_LCC1(DEV).eds | |
MAC ID setting | 0 to 63 (Set using HPB or POPCOM+.) | |
Communication speed setting | 500K/250K/125Kbps (Set using HPB or POPCOM+.) | |
Communication data | Predefined Master/Slave Connection Set: Group 2 only server Dynamic connection support (UCMM): None Support for divided transmission of explicit message: Yes |
|
Network length | Total length | 100m/500Kbps, 250m/250Kbps, 500m/125Kbps |
Branch length/Total branch length | 6m or less/39m or less, 6m or less/78m or less, 6m or less/156m or less | |
Monitor LED | None | |
Number of DeviceNet™ I/O points/number of occupied channels | General-purpose input 32 points, General-purpose output 32 points Dedicated input 16 points, Dedicated output 16 points Input register 8 words Output register 8 words Input: 24byte Output: 24byte |
Basic specifications for network modules
Item | Network modules EtherNet/IP™ |
---|---|
Applicable controllers | LCC140 |
Applicable software version | LCC140: Ver. 64.07 or higher HPB/HPB-D: Ver. 24.06 or higher POPCOM+: Ver. 2.1.0 or higher |
Applicable EtherNet/IP™ specifications | Volume 1 : Common Industrial protocol(CIPTM) Edition 3.14 Volume 2 : EtherNet/IPTM Adaptation of CIP Edition 1.15 |
EtherNet/IP™ Conformance test | Compliant with CT11 |
Device profile/Device type number | Generic Device(keyable) / 2B Hex |
Vendor name/Vendor ID | YAMAHA MOTOR CO.,LTD. / 636 |
Product code | 23 |
Product revision | 1.1 |
EDS file name | Yamaha_LCC1(EIP2).eds |
Communication speed | 10Mbps / 100Mbps |
Connector specifications | RJ-45 connector (8-pole modular connector), 2 ports |
Applicable cable specifications | STP cable (double shield) with CAT 5e or higher |
Maximum cable length | 100m |
Monitor LED | Module Status(MS), Network Status(NS), Link/Activity:Port1-2 |
Number of EtherNet/IP™ I/O points/number of occupied channels | General-purpose input 32 points, General-purpose output 32 points Dedicated input 16 points, Dedicated output 16 points Input register 8 words Output register 8 words Input: 24byte Output: 24byte |
TS-S2 / TS-SH / TS-X/P Egytengelyes robotpozícionálók
Basic specifications for network modules
Item | Network modules CC-Link |
---|---|
Applicable controllers | TS-S2/TS-SH/TS-X/TS-P |
Version supporting CC-Link | Ver. 1.10 |
Remote node type | Remote device node |
Number of occupied nodes | 1 node |
Node number setting | 1 to 64 |
Communication speed setting | 10Mbps, 5Mbps, 2.5Mbps, 625Kbps, 156Kbps |
No. of CC-Link inputs/outputs | Input 16 points , Output 16 points |
Shortest distance between nodesNote1 | 0.2m or more |
Overall extension distanceNote1 | 100m/10Mbps, 160m/5Mbps, 400m/2.5Mbps, 900m/625Kbps, 1200m/156Kbps |
Monitor LED | L RUN, L ERR, SD, RDD |
Note1. These values apply when a cable that supports CC-Link Ver.1.10 is used.
Basic specifications for network modules
Item | Network modules DeviceNetTM | |
---|---|---|
Applicable controllers | TS-S2/TS-X/TS-P | |
Applicable DeviceNetTM specifications | Volume 1 Release2.0/Volume 2 Release2.0 | |
Device Profile | Generic Device (device number 0) | |
Number of occupied CH Note1 | Input 6ch, Output 6ch | |
MAC ID setting | 0 to 63 | |
Communication speed setting | 500Kbps, 250Kbps, 125Kbps | |
DeviceNetTM inputs/outputs | Input 16 points, Output 16 points | |
Network length | Overall extension distance | 100m/500Kbps, 250m/250Kbps, 500m/125Kbps |
Branch length | 6m or less | |
Overall branch length | 39m or less/500Kbps, 78m or less/250Kbps, 156m or less/125Kbps | |
Monitor LED | Module, Network |
Basic specifications for network modules
Item | Network modules EtherNet/IPTM |
---|---|
Applicable controllers | TS-S2 / TS-SH /TS-SH/TS-X/TS-PNOTE |
Applicable EtherNet/IPTM specifications | Volume1 : Common Industrial Protocol(CIPTM) Edition 3.8 Voluime2 : EtherNet/IPTM Adaptation Edition 1.9 |
Device type | Generic Device (device number 43) |
Number of occupied CH | Input 6ch, Output 6ch |
Ethernet interface | 10BASE-T/100BASE-TX |
Network length | 100m |
Monitor LEDD | MS, NS, Activity, Link |
Note. Supported by controller software version V1.10.121 or later. Necessary parameters can be set with the support tool, HT-1 (V1.13 or later) and TSManager (V1.3.3 or later).
Basic specifications for network modules
Item | Network modules PROFINET |
---|---|
Applicable controllers | TS-S2/TS-SH/TS-X/TS-P |
Network specification conformance | PROFINET IO V2.2 |
Conformance class | Conformance Class B / IO Device |
Input/output data size | Input 6 words, output 6 words |
Transmission speed | 100Mbps(Auto-negotiation) |
Network length | 100m |
Monitor LED | MS, NS, Activity, Link |
Note. Supported by controller software version V1.14.136 or later. Necessary parameters can be set with the support tool, HT-1 (V1.16 or later) and TSManager (V1.4.4 or later).
SR1-X / SR1-P egytengelyes robotpozícionálók
Basic specifications for network modules
item | Network modules CC-Link |
---|---|
Applicable controllers | ERCX/SR1-P/SR1-X/SRCP30/DRCX |
Version supporting CC-Link | Ver. 1.10 |
Remote node type | Remote device node |
Number of occupied nodes | Two nodes fixed |
Node number setting | 1 to 63 |
Communication speed setting | 10Mbps, 5Mbps, 2.5Mbps, 625Kbps, 156Kbps |
No. of CC-Link I/ONote1 | General input 32 points, General output 32 points, Dedicated input 16 points, Dedicated Output 16 points |
Parallel external I/O (ERCX, SRCP30, DRCX only) |
All points usable as parallel external I/O for controller. Each point controllable from master station sequencer (PLC) by emulated serialization, regardless of robot program. |
Shortest distance between nodesNote2 | 0.2m or more |
Overall lengthNote2 | 100m/10Mbps, 160m/5Mbps, 400m/2.5Mbps, 900m/625Kbps, 1200m/156Kbps |
Monitor LED | RUN, ERR, SD, RD |
Note1. Controller I/Os are updated every 10ms.
Note2. These values apply when a cable that supports CC-Link Ver 1.10 is used.
Basic specifications for network modules
Item | Network modules DeviceNet™ | |
---|---|---|
Applicable controllers | ERCX/SR1-P/SR1-X/SRCP30/DRCX | |
Applicable DeviceNet™ specifications | Volume 1 Release2.0/Volume 2 Release2.0 | |
Device type | Generic Device (device number 0) | |
Number of occupied CH | Input 2ch Note1, Output 2ch Note1 | |
MAC ID setting | 0〜63 | |
Communication speed setting | 500Kbps, 250Kbps, 125Kbps | |
DeviceNet™ I/O Note2 | General input 16 points Note3, General output 16 points Note3, Dedicated input 16 points, Dedicated Output 16 points | |
Parallel external I/O (ERCX, SRCP30, DRCX only) |
All points usable as parallel external I/O for controller. Each point controllable from master station sequencer (PLC) by emulated serialization, regardless of robot program. |
|
Network length |
Overall length Note4 | 100m/500Kbps, 250m/250Kbps, 500m/125Kbps |
Branch length/Overall branch length | 6m or less/39m or less, 6m or less/78m or less, 6m or less/156m or less | |
Monitor LED | Module, Network |
Note1. Inputs / Outputs are 12ch each when using SR1-P / SR1-X with extension model.
Note2. Controller I/Os are updated every 10ms.
Note3. General Inputs / Outputs are 32 each when using SR1-P / SR1-X with extension model.
Note4. These values apply when a thick cable is used. The distance is less when a fine cable is used or when thick and fine cables are mixed in use.
Basic specifications for network modules
Item | Network modules PROFIBUS |
---|---|
Applicable controllers | ERCX/SRCP30/SR1-P/SR1-X/DRCX |
Communication profile | PROFIBUS-DP slave |
Number of occupied nodes | 1node |
Setting of station address | 0 to 126 |
Communication speed setting | 9.6Kbps, 19.2Kbps, 93.75Kbps, 187.5Kbps, 500Kbps, 1.5Mbps, 3Mbps, 6Mbps, 12Mbps (automatic recognition) |
PROFIBUS I/O Note | General input 32 points, General output 32 points, Dedicated input 16 points, Dedicated Output 16 points |
Parallel external I/O (ERCX / DRCX only) |
All points usable as parallel external I/O for controller. Each point controllable from master station sequencer (PLC) by emulated serialization, regardless of robot program. |
Overall length | 100m/12Mbps, 200m/1.5Mbps, 400m/500Kbps, 1000m/187.5Kbps, 1200m/9.6K · 19.2K · 93.75Kbps |
Note. The shortest I/O update interval of the controller is 10ms but the actual I/O update time varies depending on the update time with the master station.
EterNet
Basic specifications for network modules
Item | Network modules Ethernet |
---|---|
Applicable controllers | ERCX/SRCP30/DRCX |
Network specification | As specified for Ethernet (IEEE802.3) |
Connector specification | RJ-45 connector (8-pole modular connector) 1 port |
Baud rate / Communication mode | 10Mbps (10BASE-T) / Half Duplex (Half-duplex) |
Network protocol | Application layer: TELNET / Transport layer: TCP / Network layer: IP, ICMP, ARP / Data link layer: CSMA/CD / Physical layer: 10BASE-T |
Number of simultaneous log inputs | 1 |
Setting of IP address, etc. | Set from HPB / HPB-D |
Monitor LED | Run, Collision, Link, Transmit, Receive |
RCX320/340 többtengelyes vezérlők
RCX320/340 : CC-Link, DeviceNet, PROFIBUS, Ethernet, EtherNet/IP, PROFINET, EtherCAT
Basic specifications for network modules
Item | Network modules CC-Link |
---|---|
Applicable controllers | RCX221 / RCX222 / RCX320 / RCX340 |
Version supporting CC-Link | Ver. 1.10 |
Remote station type | Remote device node |
Number of occupied stations | Fixed to 4 stations |
Station number setting | 1 to 61 (Set from the programming box or support software) |
Communication speed setting | 10Mbps, 5Mbps, 2.5Mbps, 625Kbps, 156Kbps (set from the Rotary swich on board) |
No. of CC-Link I/O Note1 | General input 96 points, General output 96 points, Dedicated input 16 points, Dedicated output16 points |
Parallel external I/O Note2 | A function that simulates serial communication enables individual control of the various points from a master sequencer, regardless of the robot program. |
Shortest distance between nodes Note3 | 0.2 m or more |
Overall length Note3 | 100m/10Mbps, 150m/5Mbps, 200m/2.5Mbps, 600m/625Kbps, 1200m/156Kbps |
Monitor LED | RUN, ERR, SD, RD |
Note1. In case of RCX221/RCX222, the controller I/Os are updated every 10ms. For RCX320 / 340, the controller I/Os are updated every 5ms for the shortest. The actual update time changes depending on the communication cycle of the master unit.
Note2. With RCX 141/142, the exclusive input of the parallel I/O cannot be used other than the interlock input.With RCX221 / 222, the exclusive input of the parallel I/O cannot be used. (The interlock input terminal is located on the SAFETY connector side.)
Note3.n These values apply when a cable that supports CC-Link Ver.1.10 is used.
Basic specifications for network modules
Item | Network modules DeviceNet™ | |
---|---|---|
Applicable controllers | RCX221 / RCX222 / RCX320 / RCX340 | |
Applicable DeviceNet™ specifications | Volume 1 Release2.0 / Volume 2 Release2.0 | |
Device Profile Name | Generic Device (device number 0) | |
Number of occupied CH Note1 | Normal: Input/output 24ch each, Compact: Input/output 2ch each | |
MAC ID setting | 0 to 63 | |
Transmission speed setting | 500Kbps, 250Kbps, 125Kbps (set using DIP switch on board) | |
DeviceNet™ I/O Note2 | Normal | General input 96 points, General output 96 points, Dedicated input 16 points, Dedicated output 16 points |
Compact | General input 16 points, General output 16 points, Dedicated input 16 points, Dedicated output 16 points | |
Parallel external I/O Note3 | The master module and up to four ports can be controlled regardless of the robot program by using the pseudoserialization function. | |
Network length | Overall length Note4 | 100m/500Kbps, 250m/250Kbps, 500m/125Kbps |
Branch length / Overall branch length | 6m max./39m max., 6m max./78m max., 6m max./156m max. | |
Monitor LED | MS (Module Status), NS (Network Status) |
Note1. Use the robot parameter to select Normal or Compact. However, with the controllers earlier than Ver.9.08 of RCX221 / 222, this selection is not available and the setting remains the same as Normal.
Note2. In case of RCX221/RCX222, the controller I/Os are updated every 10ms. For RCX320 / 340, the controller I/Os are updated every 5ms for the shortest. The actual update time changes depending on the communication cycle of the master unit.
Note3. With RCX221 / 222, the exclusive input of the parallel I/O cannot be used. (The interlock input terminal is located on the SAFETY connector side.)
Note4. These values apply when a thick cable is used. The distance is less when a fine cable is used or when thick and fine cables are mixed in use.
Basic specifications for network modules
Item | Network modules PROFIBUS |
---|---|
Applicable controllers | RCX221 / RCX222 / RCX320 / RCX340 |
Communication profile | PROFIBUS-DP slave |
Number of occupied nodes | 1 node |
Setting of station address | 1 to 99 (set using Rotary switch on board) |
Setting of communication speed | 9.6Kbps, 19.2Kbps, 93.75Kbps, 187.5Kbps, 500Kbps, 1.5Mbps, 3Mbps, 6Mbps, 12Mbps (automatic recognition) |
PROFIBUS I/O Note1 | General input 96 points, General output 96 points, Dedicated intput 16 points, Dedicated output 16 points |
Parallel external I/O Note2 | The master module and up to four ports can be controlled regardless of the robot program by using the pseudoserialization function. |
Overall length | 100m/3M·6M·12Mbps, 200m/1.5Mbps, 400m/500Kbps, 1000m/187.5Kbps, 1200m/9.6K·19.2K·93.75Kbps |
Monitor LED | RUN, ERR, SD, RD, DATA-EX |
Note1. In case of RCX221/RCX222, the shortest I/O update interval of the controller is 10ms but the actual I/O update time varies depending on the update time with the master station. For RCX320 / 340, the controller I/Os are updated every 5ms for the shortest. The actual update time changes depending on the communication cycle of the master unit.
Note2. With RCX221 / 222, the exclusive input of the parallel I/O cannot be used. (The interlock input terminal is located on the SAFETY connector side.)
EtherNet
Basic specifications for network modules
Item | Network modules Ethernet |
---|---|
Applicable controllers | RCX221 / RCX222 / RCX320 / RCX340 |
Network specification | As specified for Ethernet (IEEE802.3) |
Connector specification | RJ-45 connector (8-pole modular connector) 1 port |
Baud rate | 10Mbps (10BASE-T) |
Communication mode | Half Duplex (Half-duplex) |
Network protocol | Application layer: TELNET / Transport layer: TCP / IP Network layer: IP, ICMP, ARP / Data link layer: CSMA/CD / Physical layer: 10BASE-T |
Number of simultaneous log inputs | 1 |
Setting of IP address, etc. | Set from RPB |
Monitor LED | Run, Collision, Link, Transmit, Receive |
Basic specifications for network modules
Item | Network modules EtherNet/IP™ | ||
---|---|---|---|
Controller model | RCX320/RCX340 | ||
Network specifications | Conforms to Ethernet (IEEE 802.3). | ||
Applicable EtherNet/IP™ specifications | Volume 1 : Common Industrial protocol (CIP™) Edition 3.14 Volume 2 : EtherNet/IP™ Adaptation Edition 1.15 |
||
Device type | Generic Device (Device No. 43) | ||
Data size | 48 bytes each for input /output | ||
Transmission speed | 10 Mbps/100 Mbps | ||
Connector specifications | RJ-45 connector (8-pole modular connector) 2 port | ||
Cable specifications | Refer to “2.1 LAN cable” in Chapter 2 of this user's manual. | ||
Max. cable length | 100m | ||
EtherNet/IP™ input/output points Note | Input (48 bytes in total) |
byte 0-3 byte 4-31 |
Dedicated word input : 2 words General purpose word input : 14 words |
byte 32-33 byte 34-47 |
Dedicated bit input : 16 points General-purpose bit input : 96 points |
||
Output (48 bytes in total) |
byte 0-3 byte 4-31 |
Dedicated word output : 2 words General-purpose word output : 14 words |
|
byte 32-33 byte 34-47 |
Dedicated bit output : 16 points General-purpose bit output : 96 points |
||
Parallel external input | Regardless of the robot program, the master module and up to four por ts can be controlled using the emulated serialization function. |
||
Settings, such as IP address | The settings are made with the programming box (PBX) or RCX-Studio Pro. | ||
Monitor LEDs | Network Status, Module Status |
Note. The controller I/Os are updated every 5ms for the shortest. The actual update time changes depending on the communication cycle of the master unit.
Basic specifications for network modules
Item | Network modules PROFINET | |
---|---|---|
Applicable controllers | RCX320/RCX340 | |
Supported software versions | RCX320/RCX340 : V1.21 or later PBX/PBX-E : V1.08 or later RCX-Studio : V1.0.1 or later RCX-Studio Pro : V2.0.0 or later |
|
Network specification conformance | PROFINET IO V2.2 | |
Conformance class | Conformance Class B / IO Device | |
Vendor Name / Vendor_ID | YAMAHA MOTOR CO.,LTD. / 0x02D5 | |
Station Type / Device_ID | YAMAHA RCX3 PROFINET / 0x0001 | |
Product revision | 1.00 | |
GSD file name | GSDML-V2.3-YMC-RCX3-20150203.xml | |
Transmission speed | 100Mbps( Auto-negotiation) | |
Connector specifications | RJ-45 connector (8-pole modular connector) 2 por ts | |
Conforming cable specifications | CAT 5e or higher STP cable (double shield) | |
Max. cable length | 100m | |
Monitor LEDs | Module Status(MS), Network Status(NS), Link/Activity:Port1-2 | |
Input /output data size Note | Input : 48bytes | Dedicated word input 2 words (4 bytes) |
General-purpose word input 14 words (28 bytes) | ||
Dedicated bit input 16 bits (2 bytes) | ||
General-purpose bit input 96 bits (12 bytes) | ||
Reserved area 2 bytes | ||
Output : 48bytes | Dedicated word output 2 words (4 bytes) | |
General-purpose word output 14 words (28 bytes) | ||
Dedicated bit output 16 bits (2 bytes) | ||
General-purpose bit output 96 bits (12 bytes) | ||
Reserved area 2 bytes |
Note. The controller I/Os are updated every 5ms for the shortest. The actual update time changes depending on the communication cycle of the master unit.
Basic specifications for network modules
Item | Network modules EtherCAT | |
---|---|---|
Applicable controllers | RCX320/RCX340 | |
Supported software versions | RCX320/RCX340 : V1.62 or later PBX/PBX-E : V1.13 or later RCX-Studio Pro : V2.1.9 or later |
|
ESI file name | YAMAHA RCX340 EtherCAT 1_00.xml | |
Transmission speed | 100Mbps(Auto-negotiation) | |
Connector specifications | RJ-45 connector (8-pole modular connector) 2 ports | |
Conforming cable specifications | CAT 5e or higher STP cable (double shield) | |
Max. cable length | 100m | |
Monitor LEDs | RUN, ERROR, Link/Activity:Port1-2 | |
Input /output data size Note | Input : 48bytes | Dedicated word input 2 words (4 bytes) |
General-purpose word input 14 words (28 bytes) | ||
Dedicated bit input 16 bits (2 bytes) | ||
General-purpose bit input 96 bits (12 bytes) | ||
Reserved area 2 bytes | ||
Output : 48bytes | Dedicated word output 2 words (4 bytes) | |
General-purpose word output 14 words (28 bytes) | ||
Dedicated bit output 16 bits (2 bytes) | ||
General-purpose bit output 96 bits (12 bytes) | ||
Reserved area 2 bytes |
Note. The controller I/Os are updated every 5ms for the shortest. The actual update time changes depending on the communication cycle of the master unit.